The LIAD series detectors will be discontinued upon depletion of existing stock. Please contact Ophir and purchase the equivalent RM9 series detectors.
- Discontinued upon depletion of remaining stock
- Built-in lock in amplifier to reduce noise and drift
- Broad wavelength range from 0.15 to 12 um
- Power measurement down to 300 fW
- Capable of a pulsed source with 200 Hz or higher frequency
- Chopper included See All Features
Compatible Power Meters
Newport offers a comprehensive range of optical power meters from low cost, hand-held meters to the most advanced dual-channel benchtop meter available in the market. Presented here is a list of meters compatible with the LIAD Series sensors. For more detailed information about our power meters, please see our Optical Power Meter Guide.
| 1919-R | 843-R | 844-PE-USB | |
|---|---|---|---|
| Measurement Modes |
Power Single Shot Energy Track (Position + Stability) Pulsed Power |
Power Single Shot Energy Track (Position) |
Power Single Shot Energy Track (Position + Stability) |
| Analog Bandwidth | 15 Hz | 15 Hz | 15 Hz |
| Data Storage | Limited by USB memory size |
|
Via PMManager |
| Measurement Rate per Second | 15 | 15 | 15 |
| Trigger In/Out | No | No | No |
| Computer Interface |
USB RS-232 |
|
USB |
Additionally, please refer to Newport Power Meter and Detector Legacy and Compatibility for a complete list of meters that are compatible with this model.
Specifications
Features
Built-in lock in amplifier to reduce noise and drift
The LIAD series Radiometers use a pyroelectric or photodiode sensor in conjunction with chopped CW or quasi CW radiation, using a digitally synthesized lock-in amplifier to reduce external noise to a minimum. When connected to a compatible optical power meter, you can measure a calibrated power at a very low power level. To maintain calibration uncertainty and guarantee performance, we recommend annual recalibration.
Chopper Included
The signal is passed through the 18Hz chopper, included in the products, and the chopped signal is detected by the sensor. All signals not at this 18Hz frequency are suppressed. The chopper must be placed close to the signal source so as to eliminate radiation from an unwanted source. There is a 1/4-20 hole on each side of the chopper housing, to allow a large number of mounting options.
Power Measurement down to 300 fW
Capable of a Pulsed Source with 200 Hz or Higher Frequency
Resources
2D Product Drawings
LIAD-PD-300N Dimensional Drawing.pdf(161 kB, PDF) LIAD-PY-100M Dimensional Drawing.pdf(72 kB, PDF)
Technical Notes
LIAD-PD-300N User Notes(107.5 kB, PDF) LIAD-PY-100M User Notes(142.5 kB, PDF)
Literature
LIAD Series Amp Detectors Datasheet(2.2 MB, PDF)