XYZ Piezo Linear Stage, 100 µm Nanopositioning, Strain-gauge, Vacuum

The NPXYZ100SGV6 Vacuum Compatible Three Axis Nanopositioning Linear Stage is a 100 µm travel piezo-based stage providing nanometer resolution motion in XYZ. It is ideally suited for nanopositioning of small components such as mirrors, fibers, laser diodes, micro-optics, sensors, or cellular samples. Applications include optical delay lines, path length changes of interferometers, laser lithography, scanning microscopy, and patch-clamping, among others. NPX stages feature highly reliable, multi-layer, low-voltage piezoelectric transducer (PZT) stacks for high-duty cycle operations. A sophisticated, FEA-optimized, parallelogram solid state flexure guide system ensures perfect parallel motion. Due to the frictionless guide, NPX stages are maintenance-free, are not subject to wear and provide rapid response and fast settling performance making them suitable for use in dynamic processes such as high-frequency error compensation, tracking, fast stepping or continuous scanning.
The closed-loop version features a high resolution strain-gauge position sensor for highly accurate and repeatable motion, that also compensates for actuator creep. It uses a full Wheatstone bridge design and can be operated in either open or closed-loop control. Fastening is easy with tapped and alignment pin holes at the top and bottom plates. For mounting to optical tables or other components with the same hole grid, use adapter plate NPX-BP. Like with all piezo flexure devices, excessive moment loads and side forces acting between the top plate and the housing should be avoided during fastening.
Use with the NPC3SG Nanopositioning Amplifier.
Specifications
- Travel Range0.1 mm
- Axes of TravelXYZ
- Axial Load Capacity40/40/32 N
- Vertical Load Capacity30 N
- Axial Stiffness1 N/µm
- FeedbackStrain-gauge
- Cable Length2 m
- Vacuum Compatibility10-6 Torr
- Capacitance1.8 µF
- Closed Loop Repeatability, Typical30 nm
- Closed Loop Resolution4 nm
- Closed Loop Travel80 µm
- Open Loop Resolution0.4 nm
- Open Loop Travel100 µm
- Resonant Frequency, 105g Load190/180/250 Hz
- Resonant Frequency, 300g Load110/110/150 Hz
- Resonant Frequency, 80g Load210/200/300 Hz
- Resonant Frequency, Unloaded500/550/480 Hz
- Weight160 g
- RoHSCompliant
Resources & Downloads
3D Product Models
Literature
NPX Data Sheet(1.6 MB, PDF) Vaccum Compatible Products Brochure(3.8 MB, PDF)
2D Product Drawings
NPXYZ100 Series-S(108.6 kB, PDF)
Manuals
NanoPositioning NPX & PSM User's Manual(139.7 kB, PDF) NPC & NPCSG Series Amplifiers User's Manual(1 MB, PDF)
Technical Notes
Resonant Frequency Tech Note(78.4 kB, PDF)
Related Products
Accessories
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | NPX-BPBase Plate, Nanopositioning Translation Stages |
Similar
| Compare | Description | Drawings, CAD & Specs | Avail. | Price | ||
|---|---|---|---|---|---|---|
![]() | NPXY100SGV6XY Piezo Linear Stage, 100 µm Nano-Positioning, Strain-gauge, Vacuum | |||||
![]() | NPXY100SGPiezo XY Linear Stage, 100 µm Nanopositioning, Strain-gauge | |||||
![]() | NPXYZ100SGPiezo XYZ Linear Stage, 100 µm Nanopositioning, Strain-gauge | In Stock | ||||
![]() | NPXYZ100XYZ Piezo Linear Stage, Open-loop, 100 µm Nanopositioning | |||||
![]() | NPXYZ100V6XYZ Linear Stage, Vacuum Open-loop Piezo Stack, 100 μm |